Détail de la notice
Titre du Document
Leak detection in pressure tubes of a pressurised heavy water reactor by acoustic emission technique
Auteur(s)
KALYANASUNDARAM P. ; BALDEV RAJ ; KASIVISWANATHAN K. V. ; ...
Résumé
Leak detection in the fuel channels is one of the challenging problems during the in-service inspection (ISI) of Pressurised Heavy Water Reactors (PHWRs). In this paper, the use of an acoustic emission (AE) technique together with AE signal analyses is described, to detect a leak that was encountered in one (or more) of the 306 fuel channels of the Madras Atomic Power Station (PHWR), Unit 1. The paper describes the problems encountered during the ISI, the experimental methods adopted and the results obtained. Results obtained using acoustic emission signal analysis are compared with those obtained from other leak detection methods used in such cases
Editeur
Non-Destructive Testing Society of Great Britain
Identifiant
ISSN : 0007-1137 CODEN : BJNTAS
Source
British Journal of Non-Destructive Testing A. 1992, vol. 34, n° 11, pp. 539-543 [bibl. : 14 ref.]
Langue
Anglais
Pour les membres de la communauté du CNRS, ce document est autorisé à la reproduction à titre gratuit.
Pour les membres des communautés hors CNRS, la reproduction de ce document à titre onéreux sera fournie sous réserve d’autorisation du Centre Français d’exploitation du droit de Copie.