Détail de la notice
Titre du Document
A practical formula to calculate critical value of the interphase reactor in a six-phase diode rectifier with tap-changer
Auteur(s)
QIJUN PAN ; WEIMING MA ; DEZHI LIU
Corporation(s) du ou des auteurs
IEEE Industrial Electronics Society USA (Organisateur de congrès)
Résumé
This paper presents a formula to calculate the critical value of interphase reactor (IPR) in a six-phase rectifier with tap-changer. Simulation and experimental results verify the validity of the calculation approach. The calculated critical value Is accurate enough to meet the engineering need. The parameter of the reactor must be larger than the critical value. On the basis of theoretical analysis, a simple and effective method is provided to design the interphase reactor. On balance, the above achievements play an important role in the design of the interphase reactor.
Editeur
IEEE
Type du document
Conférence : IEEE Industial Electronics Society. Annual conference, 30, Busan, KOR, 2004-11-02
Identifiant
ISSN : ISBN : 0-7803-8730-9
Source
A. 2004, [Vol1, 696-699] [bibl. : 7 ref.] [nb. vol. : 3]
Langue
Anglais
Pour les membres de la communauté du CNRS, ce document est autorisé à la reproduction à titre gratuit.
Pour les membres des communautés hors CNRS, la reproduction de ce document à titre onéreux sera fournie sous réserve d’autorisation du Centre Français d’exploitation du droit de Copie.